Daikin multi-split type air conditioners require only a single outdoor unit to maintain optimum comfort in up to five rooms. The many benefits offered by a multi-split system are enhanced by Daikin's DC Inverter control and next-generation R-32 refrigerant.

Features

  • Single outdoor unit is connectable to up to five indoor units
  • Compact and powerful system enables an outdoor unit to connect indoor units up to 205% of outdoor capacity
  • Two latest wall-mounted type and duct-connected type indoor units are connectable
  • Indoor units have a wide range of capacity classes from 2.5 to 7.0 kW
  • All systems use next generation R-32 refrigerant
  • DC Inverter enables air conditioners to achieve high energy efficiency.

Download Catalogue

Features

Single outdoor unit is connectable to up to five indoor units

Compact and powerful system enables an outdoor unit to connect indoor units up to 205% of outdoor capacity

Connectable to up 205% of outdoor capacity

In most family homes, it is unusual for all indoor units to operate together. During the day, people tend to use shared spaces such as the living room. At night, they mainly use the bedrooms.

This is a reason why a single multi-split outdoor unit can be connected to indoor units which exceed its capacity. Daikin Multi-Split Type can be connectable by 149% to 205%.

Two latest wall-mounted type and duct-connected type indoor units are connectable

Indoor units have a wide range of capacity classes from 2.5 to 7.0 kW

All systems use next generation R-32 refrigerant

As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuosly researching refrigerants as well new technologies that can reduce energy consumption. Use of refrigerants with a lower impact on global warming is urgently required as climate change has become one of the most critical global issues. Daikin has now adopted R-32. This next-generation refrigerant does not deplete the ozone layer and has a lower impact on global warming.

DC Inverter enables air conditioners to achieve high energy efficiency

High COPs of 4.30 to 4.92

The MKM65P achieves a COP of 4.92 thanks to Daikin's DC Inverter control and next-generation R-32 refrigerant.

Lineup/Specifications

Model Name MKM65PV14 MKM80PV14 MKM95PV14 MKM105PV14
Power supply 1 phase, 220-240 V, 50 Hz
Number of ports 4 5
Max. connected indoor units capacity kW 12.0 15.6

Casing colour

Ivory White
Compressor type Hermetically sealed swing type
Refrigerant type R-32
Sound Pressure Level Rated dB(A) 48 53
Dimensions H x W x D mm 695 x 930 x 350 990 x 940 x 320
Mechine Weight kg 49 83
Operation range 'CDB 10 to 46
Max. pipng length m 60 (total) 70 (total) 80 (total)
30 (for one room)
Additional charge g/m Chargeless
Max. level difference m 15 (between indoor and outdoor units) / 7.5 (between indoor units)

Please refer to the catalogue for the information regarding the combinations of indoor and outdoor units and the detailed specifications.

Model Name FTKJ25NVM4W FTKJ25NVM4S FTKJ35NVM4W
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour White Silver White
Airflow H m3/min (cfm) 8.9 (313) 10.9 (385)

Sound pressure level

H/L/SL dB (A) 38/25/19 45/26/20
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 303 x 998 x 212
Mechine Weight kg 12
Piping connection Liquid mm ǿ6.4
Gas ǿ9.5
Drain ǿ18.0
Heat insulation Both equid and gas pipes
Model Name FTKJ35NVM4S FTKJ50NVM4W FTKJ50NVM4S
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour Silver White Silver
Airflow H m3/min (cfm) 10.9 (385)

Sound pressure level

H/L/SL dB (A) 45/26/20 46/35/29
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 303 x 998 x 212
Mechine Weight kg 12
Piping connection Liquid mm ǿ6.4
Gas ǿ9.5 ǿ12.7
Drain ǿ18.0
Heat insulation Both equid and gas pipes

Please refer to the catalogue for the information regarding the combinations of indoor and outdoor units and the detailed specifications.

Model Name CTKM25PV14 CTKM35PV14 CTKM42PV14
Power supply 1 phase, 220-240 V, 50 Hz
Front panel colour Pure white (N9.5)
Airflow H m3/min (cfm) 10.1 (357) 10.8 (381) 11.5 (406)

Sound pressure level

H/L/SL dB (A) 40/26/19 41/27/23 42/30/27
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 283 x 770 x 223
Mechine Weight kg 8 9
Piping connection Liquid mm ǿ6.4
Gas ǿ9.5
Drain ǿ16.0
Heat insulation Both equid and gas pipes
Model Name CTKM50PV14 CTKM60PV14 CTKM71PV14
Power supply 1 phase, 220-240 V, 50 Hz
Front panel colour Pure white (N9.5)
Airflow H m3/min (cfm) 11.8 (417) 15.4 (544) 18.2 (643)

Sound pressure level

H/L/SL dB (A) 43/34/31 45/35/32 46/37/33
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 283 x 770 x 223 290 x 1050 x 250 340 x 1050 x 248
Mechine Weight kg 9 12 14
Piping connection Liquid mm ǿ6.4
Gas ǿ12.7 ǿ15.9
Drain ǿ16.0 ǿ18.0
Heat insulation Both equid and gas pipes

Please refer to the catalogue for the information regarding the combinations of indoor and outdoor units and the detailed specifications.

Model Name Width of 700 mm Width of 900 and 1.100 mm
CDKP25PV14 CDKP35PV14 CDKM25PV14
Power supply 1 phase, 220-240 V, 50 Hz
Airflow H m3/min (cfm) 8.7 (307) 9.5 (335)

Sound pressure level

H/L/SL dB (A) 35/31/29
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 200 x 700 x 620 200 x 900 x 620
Mechine Weight kg 21 25
Piping connection Liquid mm ǿ6.4
Gas ǿ9.5
Drain VP20 (Inside diameter ǿ20, Outside diameter ǿ26)
External static pressure Pa 30 40
Model Name Width of 900 and 1.100 mm
CDKM35PV14 CDKM50PV14 CDKM60PV14
Power supply 1 phase, 220-240 V, 50 Hz
Airflow H m3/min (cfm) 10.0 (353) 12.0 (424) 16.0 (565)

Sound pressure level

H/L/SL dB (A) 35/31/29 37/33/31 38/34/32
Fan Speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 200 x 900 x 620 200 x 1100 x 620
Mechine Weight kg 25 27 30
Piping connection Liquid mm ǿ6.4
Gas ǿ9.5 ǿ12.7
Drain VP20 (Inside diameter ǿ20, Outside diameter ǿ26)
External static pressure Pa 40
  • Note:
    • *1The values are for the rear-suction inlet at an external static pressure of 30 Pa. Values for the bottom-suction inlet can be obtained by adding 6 dB (A). When a duct-connected type indoor unit with a reduced external static pressure is installed, the values for the bottom-suction inlet are higher.

Please refer to the catalogue for the information regarding the combinations of indoor and outdoor units and the detailed specifications.