High Efficiency
This unit adopts high-efficiency scroll compressor and innovative energy-saving technology, and boasts an IPLV of up to 4.75.
Water Cooled (UCCP)
The DAIKIN water cooled packaged unit adopts the latest air conditioning technology and the eco-friendly R410A refrigerant. With low energy consumption, the unit features flexible application, safe and reliable operation and intelligent control, and can be widely used in industrial and commercial scenarios such as plants, shopping malls, office buildings, schools, and exhibition centers.

This unit adopts high-efficiency scroll compressor and innovative energy-saving technology, and boasts an IPLV of up to 4.75.
All models are available with multiple levels of static pressure, while an optional air plenum is available for models UCCP18BP - UCCP75BP in all kinds of application. Electric heater is optional.
UCCP units have eight protection functions, which can provide comprehensive protection for the unit and system.
| Parameter | UCCP18BP | UCCP30BP | UCCP35BP | UCCP55BP | UCCP75BP | UCCP85BP | UCCP100BP | UCCP120BP | UCCP135BP | UCCP150BP | UCCP170BP | UCCP190BP | UCCP210BP |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Cooling Capacity W | 16,500 | 25,000 | 32,000 | 51,000 | 72,500 | 85,000 | 95,000 | 117,000 | 135,000 | 155,000 | 168,000 | 188,000 | 205,000 |
| Nominal Cooling Power Input W | 4,160 | 7,100 | 9,000 | 13,000 | 20,300 | 22,500 | 24,500 | 27,500 | 33,500 | 38,500 | 42,500 | 47,000 | 53,000 |
| Air Flow m³/h | 2,880 | 4,200 | 6,800 | 8,000 | 1,150 | 1,400 | 17,000 | 19,800 | 21,500 | 24,600 | 26,000 | 28,800 | 33,000 |
| Standard External Static Pressure Pa | 80 (10) | 100 (10) | 100 (10) | 150 (10) | 150 (10) | 200 | 250 | 250 | 300 | 300 | 350 | 350 | 350 |
| Optional External Static Pressure Pa | 50/100 | 50/150 | 50/200 | 100/200 | 200/250 | 300/400 | 150/350 | 150/350 | 200/450 | 200/450 | 200/400/500 | 200/400/500 | 200/400/500 |
| Sound Pressure Level dB(A) | 52 | 63 | 65 | 67 | 70 | 72 | 74 | 75 | 76 | 77 | 77 | 78 | 79 |
| Capacity Adjust Stage % | 100, 0 | 100, 50, 0 | 100, 50, 0 | 100, 67, 33, 0 | 100, 50, 0 | 100, 78, 61, 39, 22, 0 | 100, 78, 61, 39, 22, 0 | 100, 67, 33, 0 | 100 , 88, 71, 57, 43, 29, 14, 0 | 100, 50, 0 | 100, 85, 55, 44, 11, 0 | 100, 80, 60, 40, 20, 0 | 100, 91, 82, 73, 63, 54, 45, 36, 27, 18, 9, 0 |
| Power Supply | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz | 380-415V/3N-/50Hz |
| Refrigerant Type | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A |
| Compressor Type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type | Fully hermetic scroll type |
| Compressor (Qty.) Set | 1 | 2 | 2 | 2 | 2 | 3 | 3 | 2 | 3 | 2 | 3 | 3 | 4 |
| Condenser Type | Tube in tube | Tube in tube | Tube in tube | Tube in tube | Tube in tube | Shell and tube | Shell and tube | Shell and tube | Shell and tube | Shell and tube | Shell and tube | Shell and tube | Shell and tube |
| Condenser (Water Flow) m³/h | 3.55 | 5.38 | 6.88 | 10.97 | 15.59 | 18.28 | 20.43 | 25.16 | 29.03 | 33.33 | 36.12 | 40.42 | 44.08 |
| Condenser (Water Pressure Drop) kPa | 53 | 32 | 60 | 60 | 64 | 25 | 28 | 52 | 48 | 54 | 52 | 50 | 57 |
| Evaporator Type | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned | Finned |
| Throttle Mode | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube | Capillary tube |
| Fan Type | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet | Centrifugal low-noise double-air-inlet |
| Fan Drive Method | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission | V-belt transmission |
| Filter (Dimension) mm | 797 x 625 | 877 x 625 | 917 x 795 | 1,277 x 760 | 1,597 x 805 | 527 x 653 | 561 x 653 | 594 x 653 | 661 x 653 | 661 x 653 | 661 x 757 | 741 x 779 | 822 x 779 |
| Filter (Qty.) Pcs | 1 | 1 | 1 | 1 | 1 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| Outline Dimension (Length) mm | 1,175 | 1,175 | 1,175 | 1,585 | 1,585 | 1,905 | 2,000 | 2,180 | 2,380 | 2,380 | 2,380 | 2,620 | 2,860 |
| Outline Dimension (Width) mm | 660 | 660 | 660 | 730 | 830 | 1,055 | 1,055 | 1,055 | 1,055 | 1,215 | 1,215 | 1,215 | 1,215 |
| Outline Dimension (Height) mm | 1,600 (1,880) | 1,600 (1,880) | 1,880 (2,150) | 1,900 (2,160) | 1,985 (2,350) | 1,985 | 1,985 | 1,985 | 1,985 | 1,985 | 2,060 | 2,060 | 2,060 |
| Weight of cooling only unit kg | 205 (220) | 260 (275) | 310 (325) | 440 (470) | 560 (600) | 770 | 805 | 835 | 925 | 1,005 | 1,155 | 1,240 | 1,395 |
| Models of cooling only unit with electric heater | UCCP18BDP | UCCP30BDP | UCC35BDP | UCCP55BDP | UCCP75BDP | UCCP85BDP | UCCP100BDP | UCCP120BDP | UCCP135BDP | UCCP150BDP | UCCP170BDP | - | - |
| Electrical heating capacity W | 6,000 | 9,000 | 1,200 | 21,000 | 27,000 | 36,000 | 42,000 | 48,000 | 48,000 | 60,000 | 60,000 | 55,000 (HD55A) | 55,000 (HD55A) |
| Heating Power Input W | 6,370 (6,370) | 10,100 (10,100) | 13,500 (14,200) | 23,200 (23,900) | 29,200 (30,000) | 40,000 | 46,000 | 53,500 | 55,500 | 67,500 | 71,000 | 66,000 | 66,000 |
| Weight of unit with electric heater kg | 210 (225) | 270 (285) | 325 (340) | 460 (490) | 585 (625) | 810 | 850 | 885 | 975 | 1,060 | 1,210 | - | - |

FDR-QY1(4)
Concealed high static pressure ducted Packaged AC unit for long duct runs.

FVPR-QY1(4)
Floor standing Packaged Inverter AC with duct connection to distribute air to multiple areas at once.

UATQ-C Series
Equipped with a high-efficiency scroll compressor, an optimized heat exchanger, and a high-performance fan, the unit delivers optimal performance in both standard and high ambient temperatures.

FDN-H & FGN-H
This is a commercial ducted split-type air conditioning system that uses R410A refrigerant and is specifically designed for commercial spaces and factories.
Find your nearest authorised dealer or calculate the capacity your room needs.