Water Cooled (UCCP)

Water Cooled Packaged Series

Water Cooled (UCCP)

The DAIKIN water cooled packaged unit adopts the latest air conditioning technology and the eco-friendly R410A refrigerant. With low energy consumption, the unit features flexible application, safe and reliable operation and intelligent control, and can be widely used in industrial and commercial scenarios such as plants, shopping malls, office buildings, schools, and exhibition centers.

Technology
Packaged AC
Water Cooled Packaged Series

Key Features

High Efficiency

This unit adopts high-efficiency scroll compressor and innovative energy-saving technology, and boasts an IPLV of up to 4.75.

Flexible Application

All models are available with multiple levels of static pressure, while an optional air plenum is available for models UCCP18BP - UCCP75BP in all kinds of application. Electric heater is optional.

Safe & Reliable

UCCP units have eight protection functions, which can provide comprehensive protection for the unit and system.

Technical Specifications

ParameterUCCP18BPUCCP30BPUCCP35BPUCCP55BPUCCP75BPUCCP85BPUCCP100BPUCCP120BPUCCP135BPUCCP150BPUCCP170BPUCCP190BPUCCP210BP
Nominal Cooling Capacity W16,50025,00032,00051,00072,50085,00095,000117,000135,000155,000168,000188,000205,000
Nominal Cooling Power Input W4,1607,1009,00013,00020,30022,50024,50027,50033,50038,50042,50047,00053,000
Air Flow m³/h2,8804,2006,8008,0001,1501,40017,00019,80021,50024,60026,00028,80033,000
Standard External Static Pressure Pa80 (10)100 (10)100 (10)150 (10)150 (10)200250250300300350350350
Optional External Static Pressure Pa50/10050/15050/200100/200200/250300/400150/350150/350200/450200/450200/400/500200/400/500200/400/500
Sound Pressure Level dB(A)52636567707274757677777879
Capacity Adjust Stage %100, 0100, 50, 0100, 50, 0100, 67, 33, 0100, 50, 0100, 78, 61, 39, 22, 0100, 78, 61, 39, 22, 0100, 67, 33, 0100 , 88, 71, 57, 43, 29, 14, 0100, 50, 0100, 85, 55, 44, 11, 0100, 80, 60, 40, 20, 0100, 91, 82, 73, 63, 54, 45, 36, 27, 18, 9, 0
Power Supply 380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz380-415V/3N-/50Hz
Refrigerant Type R410AR410AR410AR410AR410AR410AR410AR410AR410AR410AR410AR410AR410A
Compressor Type Fully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll typeFully hermetic scroll type
Compressor (Qty.) Set1222233232334
Condenser Type Tube in tubeTube in tubeTube in tubeTube in tubeTube in tubeShell and tubeShell and tubeShell and tubeShell and tubeShell and tubeShell and tubeShell and tubeShell and tube
Condenser (Water Flow) m³/h3.555.386.8810.9715.5918.2820.4325.1629.0333.3336.1240.4244.08
Condenser (Water Pressure Drop) kPa53326060642528524854525057
Evaporator Type FinnedFinnedFinnedFinnedFinnedFinnedFinnedFinnedFinnedFinnedFinnedFinnedFinned
Throttle Mode Capillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tube
Fan Type Centrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inletCentrifugal low-noise double-air-inlet
Fan Drive Method V-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmissionV-belt transmission
Filter (Dimension) mm797 x 625877 x 625917 x 7951,277 x 7601,597 x 805527 x 653561 x 653594 x 653661 x 653661 x 653661 x 757741 x 779822 x 779
Filter (Qty.) Pcs1111166666666
Outline Dimension (Length) mm1,1751,1751,1751,5851,5851,9052,0002,1802,3802,3802,3802,6202,860
Outline Dimension (Width) mm6606606607308301,0551,0551,0551,0551,2151,2151,2151,215
Outline Dimension (Height) mm1,600 (1,880)1,600 (1,880)1,880 (2,150)1,900 (2,160)1,985 (2,350)1,9851,9851,9851,9851,9852,0602,0602,060
Weight of cooling only unit kg205 (220)260 (275)310 (325)440 (470)560 (600)7708058359251,0051,1551,2401,395
Models of cooling only unit with electric heater UCCP18BDPUCCP30BDPUCC35BDPUCCP55BDPUCCP75BDPUCCP85BDPUCCP100BDPUCCP120BDPUCCP135BDPUCCP150BDPUCCP170BDP--
Electrical heating capacity W6,0009,0001,20021,00027,00036,00042,00048,00048,00060,00060,00055,000 (HD55A)55,000 (HD55A)
Heating Power Input W6,370 (6,370)10,100 (10,100)13,500 (14,200)23,200 (23,900)29,200 (30,000)40,00046,00053,50055,50067,50071,00066,00066,000
Weight of unit with electric heater kg210 (225)270 (285)325 (340)460 (490)585 (625)8108508859751,0601,210--

Related Products

Duct Type (FDR)
Duct Type Packaged Inverter
Energy SavingFlexible DesignNighttime Quite Operation

Duct Type Packaged Inverter

FDR-QY1(4)

Concealed high static pressure ducted Packaged AC unit for long duct runs.

Duct Connection (FVPR)
Floor Standing Type - Duct Connection
Energy SavingFlexible DesignNighttime Quite Operation

Floor Standing Type - Duct Connection

FVPR-QY1(4)

Floor standing Packaged Inverter AC with duct connection to distribute air to multiple areas at once.

UATQ-C Series
Air-Cooled Rooftop Package
High EfficiencyWide Operating RangeFlat Top Design

Air-Cooled Rooftop Package

UATQ-C Series

Equipped with a high-efficiency scroll compressor, an optimized heat exchanger, and a high-performance fan, the unit delivers optimal performance in both standard and high ambient temperatures.

Static Blower (FDN-H & FGN-H)
Ducted Split Static Blower
Tough CasingConvertible Air Through Direction

Ducted Split Static Blower

FDN-H & FGN-H

This is a commercial ducted split-type air conditioning system that uses R410A refrigerant and is specifically designed for commercial spaces and factories.

Need help choosing?

Find your nearest authorised dealer or calculate the capacity your room needs.