Non-Inverter

Duct Connection Middle Static Pressure (FDMC)

SkyAir Non Inverter

R-32 refrigerant, this AC unit is up to 16% more energy-efficient compared to R-410A models. Furthermore, it features a compact design and is easy to install and maintain.

Technology
Non-Inverter
Duct Connection Middle Static Pressure (FDMC)

Key Features

Energy Saving

Energy Saving

R32 refrigerant has better heat transfer capabilities compared to R410A. This advantage results in an efficiency increase of up to 16%. The image shows the average energy efficiency ratio for different refrigerants.

Compact Design

Compact Design

The unit’s design, with a thickness of only 250mm, offers a solution for installation in spaces with limited ceiling clearance, while also saving on installation space.

Easy Maintenance

Easy Maintenance

Inspecting the drain pan or checking for debris in the drainage lines can be done without the use of any tools. The blower and motors are easily accessible by simply removing the lower rear panel and the center flange. The blower can be removed from its housing with ease, without needing to open the housing casing itself.

Technical Specifications

ParameterSDMC50AVSDMC60AVSDMC85AVSDMC85AYSDMC100AYSDMC125AYSDMC140AY
Model Name · Indoor Unit FDMC50AV14FDMC60AV14FDMC85AV14FDMC85AV14FDMC100AV14FDMC125AV14FDMC140AV14
Model Name · Outdoor Unit RC50AV14RC60AV14RC85AV14RC85AY14RC100AY14RC125AY14RC140AY14
Operating Limit °C19-4619-4619-4619-4619-4619-4619-46
Cooling Capacity (Min. - Max.) Btu/h18500240003000030000360004200048000
Cooling Capacity (Min. - Max.) Kw5.427.038.798.7910.5512.3114.07
EER W/W3.233.33.243.263.283.43.43
Total Input Power W1680213027102700322036204100
Total Current A7.469.4511.94.485.976.787.59
Power Supply V/Ph/Hz220-240/1/50 (Power from Outdoor)220-240/1/50 (Power from Outdoor)220-240/1/50 (Power from Outdoor)380-415/3/50 (Power from Outdoor)380-415/3/50 (Power from Outdoor)380-415/3/50 (Power from Outdoor)380-415/3/50 (Power from Outdoor)
Indoor Unit · Airflow (H/M/L/Q) CFM840/700/560/440890/760/620/490890/760/620/490890/760/620/4901120/1030/890/7601120/1030/890/7601120/1030/890/760
Indoor Unit · External Static Pressure (Std/High) Pa-------
Indoor Unit · Sound Pressure Level (H/M/L) Db(A)42/39/37/3544/40/37/3544/40/37/3544/40/37/3548/46/43/4048/46/43/4048/46/43/40
Indoor Unit · Unit Dimensions (HxWxD) · Unit mm246 x 840 x 840246 x 840 x 840246 x 840 x 840246 x 840 x 840288 x 840 x 840288 x 840 x 840288 x 840 x 840
Indoor Unit · Unit Dimensions (HxWxD) · Packaging mm324 x 922 x 922324 x 922 x 922324 x 922 x 922324 x 922 x 922370 x 922 x 922370 x 922 x 922370 x 922 x 922
Indoor Unit · Panel Dimensions (HxWxD) · Panel mm69 x 950 x 95069 x 950 x 95069 x 950 x 95069 x 950 x 95069 x 950 x 95069 x 950 x 95069 x 950 x 950
Indoor Unit · Panel Dimensions (HxWxD) · Packaging mm147 x 1008 x 970147 x 1008 x 970147 x 1008 x 970147 x 1008 x 970147 x 1008 x 970147 x 1008 x 970147 x 1008 x 970
Indoor Unit · Net Weight · Unit kg22222222252525
Indoor Unit · Panel Weight · Panel kg5555555
Outdoor Unit · Sound Pressure Level Db(A)52525353555860
Outdoor Unit · Dimensions (HxWxD) · Unit mm615 x 845 x 300615 x 845 x 300695 x 930 x 350695 x 930 x 350852 x 1030 x 400852 x 1030 x 400852 x 1030 x 400
Outdoor Unit · Dimensions (HxWxD) · Packaging mm679 x 992 x 414679 x 992 x 414760 x 1084 x 473760 x 1084 x 473995 x 1136 x 516995 x 1136 x 516995 x 1136 x 516
Outdoor Unit · Net Weight kg40465657647984
Pipe Connection · Liquid mm6.46.49.59.59.59.59.5
Pipe Connection · Gas mm12.712.715.915.915.915.915.9
Maximum Pipe Length m35355050505050
Maximum Pipe Elevation m20203030303030
Heat Insulation Both liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas piping

Related Products

Inverter
Ceiling Suspended (FHFC)
Energy SavingComfortable AirflowEasy Maintenance

Ceiling Suspended (FHFC)

Ceiling Suspended

Ceiling AC that needs no dedicated ceiling cavity, with long-reach airflow and low power consumption.

Inverter
Duct Connection Low Static Pressure - Width Compact (FDBF)
Comfortable AirflowQuiet ModeRefrigerant R32

Duct Connection Low Static Pressure - Width Compact (FDBF)

Hidden Concealed Duct

Capacity
2 – 6 PK
Power
1.500W – 5.300W

Blends perfectly with interior design, with no visible AC unit on the wall or ceiling.

Inverter
Ceiling Mounted Cassette Round Flow (FCFC)
Energy Saving360° AirflowEasy Maintenance

Ceiling Mounted Cassette Round Flow (FCFC)

Ceiling Cassette Round Flow

Energy-saving round flow ceiling Cassette AC with a cleanliness sensor and smart temperature control.

Inverter
Compact Multi Flow Cassette (FFFC)
Energy SavingCompact DesignComfortable Airflow

Compact Multi Flow Cassette (FFFC)

Compact Cassette

Compact 60x60 cm Cassette AC that fits standard office ceiling grids.

Need help choosing?