Energy Saving
R32 refrigerant has better heat transfer capabilities compared to R410A. This advantage results in an efficiency improvement of up to 12%. The image shows the average energy efficiency ratio for different refrigerants.
SkyAir Non Inverter
A slim design, it is suitable for any space. The DAIKIN SkyAir Non-Inverter R32 FCE Series is also capable of distributing air evenly to every corner of a room. Furthermore, it offers the advantages of energy efficiency, as well as easy installation and maintenance.


R32 refrigerant has better heat transfer capabilities compared to R410A. This advantage results in an efficiency improvement of up to 12%. The image shows the average energy efficiency ratio for different refrigerants.

With a body thickness of only 246mm, this design offers a solution for installation in spaces with limited ceiling clearance, while also saving on installation space.

Each corner is equipped with a height adjuster, allowing users to easily set the height according to their requirements. The control box is positioned in a more convenient and accessible location. It can be reached directly through the intake grille, eliminating the need to adjust any panels—a feature that saves time during installation or maintenance.
| Parameter | SCE50AVR/L | SCE71AVR/L | SCE125AYR/L |
|---|---|---|---|
| Model Name · Set | SCE50AVR/L | SCE71AVR/L | SCE125AYR/L |
| Model Name · Indoor Unit | FCE50AV14 | FCE71AV14 | FCE125AV14 |
| Model Name · Outdoor Unit | RE50AV14 | RE71AV14 | RE125AY14 |
| Total Power Input W | 1680 | 2130 | 3620 |
| Total Current A | 7.46 | 9.45 | 6.78 |
| Cooling Capacity (Min. - Max.) Btu/h | 18500 | 24000 | 42000 |
| Cooling Capacity (Min. - Max.) kW | 5.42 | 7.03 | 12.31 |
| COP W/W | 3.23 | 3.3 | 3.4 |
| Power Supply V/Ph/Hz | 220-240/1/50 / Powered from outdoor unit | 220-240/1/50 / Powered from outdoor unit | 380-415/3/50 / Powered from outdoor unit |
| Indoor Unit · Airflow (H/M/L/Q) cfm | 840/700/560/440 | 890/760/620/490 | 1120/1030/890/760 |
| Indoor Unit · Sound Pressure Level (H/M/L/Q) Db(A) | 42/39/37/35 | 44/40/37/35 | 48/46/43/40 |
| Indoor Unit · Dimensions (HxWxD) · Unit mm | 246 x 840 x 840 | 246 x 840 x 840 | 288 x 840 x 840 |
| Indoor Unit · Dimensions (HxWxD) · Packaging mm | 324 x 922 x 922 | 324 x 922 x 922 | 370 x 922 x 922 |
| Indoor Unit · Dimensions (HxWxD) · Panel mm | 65 x 950 x 950 | 65 x 950 x 950 | 65 x 950 x 950 |
| Indoor Unit · Dimensions (HxWxD) · Packaging mm | 116 x 1008 x 990 | 116 x 1008 x 990 | 116 x 1008 x 990 |
| Indoor Unit · Net Weight kg | 22 | 22 | 25 |
| Outdoor Unit · Sound Pressure Level Db(A) | 52 | 52 | 58 |
| Outdoor Unit · Dimensions (HxWxD) · Unit mm | 615 x 845 x 300 | 615 x 845 x 300 | 852 x 1030 x 400 |
| Outdoor Unit · Dimensions (HxWxD) · Packaging mm | 679 x 992 x 414 | 679 x 992 x 414 | 995 x 1136 x 516 |
| Outdoor Unit · Net Weight kg | 40 | 46 | 79 |
| Pipe Connection · Liquid mm | 6.4 | 6.4 | 9.5 |
| Pipe Connection · Gas mm | 12.7 | 12.7 | 15.9 |
| Maximum Pipe Length Between Units m | 35 | 35 | 50 |
| Maximum Installation Height Difference m | 20 | 20 | 30 |
| Heat Insulation | Liquid and Gas Pipes | Liquid and Gas Pipes | Liquid and Gas Pipes |

Ceiling Suspended
Ceiling AC that needs no dedicated ceiling cavity, with long-reach airflow and low power consumption.

Hidden Concealed Duct
Blends perfectly with interior design, with no visible AC unit on the wall or ceiling.

Ceiling Cassette Round Flow
Energy-saving round flow ceiling Cassette AC with a cleanliness sensor and smart temperature control.

Compact Cassette
Compact 60x60 cm Cassette AC that fits standard office ceiling grids.
Find your nearest authorised dealer or calculate the capacity your room needs.