Slim Duct

SkyAir Duct Connection Low Static Pressure - Height Compact (FDLF)

SkyAir Inverter

A compact, slim design that suits the look of any room, with quiet operation that is comfortable both in appearance and in the air it delivers.

Technology
Inverter
SkyAir Duct Connection Low Static Pressure - Height Compact (FDLF)

Key Features

REFRIGERANT R32

Besides being more environmentally friendly, R-32 refrigerant reduces power consumption, so there's no need to worry about soaring electricity bills

COMFORTABLE AIRFLOW

Comfortable airflow can be adjusted in up to 3 airflow levels to suit your needs

Technical Specifications

ParameterFDLF40DV14 (1 Phase)FDLF50DV14 (1 Phase)FDLF60DV14 (1 Phase)FDLF71DV14 (1 Phase)FDLF85DV14 (1 Phase)FDLF71DV14 (3 Phase)FDLF85DV14 (3 Phase)
Model Name · Indoor Unit FDLF40DV14FDLF50DV14FDLF60DV14FDLF71DV14FDLF85DV14FDLF71DV14FDLF85DV14
Model Name · Outdoor Unit RZFC40DVM4RZFC50DVM4RZFC60DVM4RZFC71DVM4RZFC85DVM4RZFC71DVM4RZFC85DVM4
Power Supply · Indoor Unit -------
Power Supply · Outdoor Unit 1 Phase, 220-240V, 50Hz1 Phase, 220-240V, 50Hz1 Phase, 220-240V, 50Hz1 Phase, 220-240V, 50Hz1 Phase, 220-240V, 50Hz3 Phase, 380-415V, 50Hz3 Phase, 380-415V, 50Hz
Cooling Capacity (Min. - Max.) KW4.0 (1.8-4.5)5.0 (2.3-5.6)6.0 (2.6-6.3)7.1 (3.2-8.0)8.5 (4.2-10.0)7.1 (3.2-8.0)8.5 (4.2-10.0)
Cooling Capacity (Min. - Max.) Btu/h13,600 (6,100-15,400)17,100 (7,800-19,100)20,500 (8,900-21,500)24,200 (10,900-27,300)29,000 (14,300-34,100)24,200 (10,900-27,300)29,000 (14,300-34,100)
Power Consumption · Cooling Kw1.191.562.072.372.982.372.98
COP kW/kW3.353.22.932.8532.85
CSPF Kwh/Kwh4.334.134.133.933.933.933.93
Indoor Unit · Color -------
Indoor Unit · Fan · Airflow Rate (H / M / L) m3/min16 / 14 /1216 / 14 /1216 / 14 /1220 / 18 / 16.520 / 18 / 16.520 / 18 / 16.520 / 18 / 16.5
Indoor Unit · Fan cfm565 / 494 / 424565 / 494 / 424565 / 494 / 424706 / 635 / 582706 / 635 / 582706 / 635 / 582706 / 635 / 582
Indoor Unit · Fan · External Static Pressure PaRated 15 (15-38)Rated 15 (15-38)Rated 15 (15-38)Rated 15 (15-38)Rated 15 (15-38)Rated 15 (15-38)Rated 15 (15-38)
Indoor Unit · Sound Pressure Level (H / M / L) dB(A)37 / 33 / 3037 / 33 / 3037 / 33 / 3040 / 37 / 3440 / 37 / 3440 / 37 / 3440 / 37 / 34
Indoor Unit · Air Filter 4 Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)Mould-proof air filter (Removeable / Washable / Mould proof)
Indoor Unit · Dimensions (HxWxD) · Unit mm200x900x620200x900x620200x900x620200x1,100x620200x1,100x620200x1,100x620200x1,100x620
Indoor Unit · Net Weight · Unit kg28282831313131
Indoor Unit · Certified Operating Range *CWB14 to 2514 to 2514 to 2514 to 2514 to 2514 to 2514 to 25
Outdoor Unit · Color Ivory WhiteIvory WhiteIvory WhiteIvory WhiteIvory WhiteIvory WhiteIvory White
Outdoor Unit · Coil · Type Micro channelMicro channelMicro channelMicro channelMicro channelMicro channelMicro channel
Outdoor Unit · Compressor · Type Hermetically sealed swing typeHermetically sealed swing typeHermetically sealed swing typeHermetically sealed swing typeHermetically sealed swing typeHermetically sealed swing typeHermetically sealed swing type
Outdoor Unit · Compressor · Motor Output KW1.21.21.21.31.61.61.6
Outdoor Unit · Refrigerant (R32) kg0.7 (Charged for 10 m)0.7 (Charged for 10 m)0.7 (Charged for 10 m)0.8 (Charged for 10 m)1.0 (Charged for 15 m)1.0 (Charged for 15 m)1.0 (Charged for 15 m)
Outdoor Unit · Sound Pressure Level · Cooling Db(A)48494950515051
Outdoor Unit · Dimensions (HxWxD) mm595 x 845 x 300595 x 845 x 300595 x 845 x 300595 x 845 x 300695 x 930 x 350695 x 930 x 350695 x 930 x 350
Outdoor Unit · Net Weight kg34343437444646
Outdoor Unit · Certified Operating Range *CDB21 to 4621 to 4621 to 4621 to 4621 to 4621 to 4621 to 46
Pipe Connection · Liquid (Flare) mmΦ6.4Φ6.4Φ6.4Φ9.5Φ9.5Φ9.5Φ9.5
Pipe Connection · Gas (Flare) mmΦ12.7Φ12.7Φ12.7Φ15.9Φ15.9Φ15.9Φ15.9
Pipe Connection · Drain · Indoor Unit mmVP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)VP25 (I.D.Φ25 x O.D. Φ32)
Pipe Connection · Drain · Outdoor Unit mmΦ 18.0 (Hole)Φ 18.0 (Hole)Φ 18.0 (Hole)Φ 18.0 (Hole)Φ 18.0 (Hole)Φ 18.0 (Hole)Φ 18.0 (Hole)
Max. Pipe Length Between Units m30 (Equivalent length 40)30 (Equivalent length 40)30 (Equivalent length 40)30 (Equivalent length 40)50 (Equivalent length 70)50 (Equivalent length 70)50 (Equivalent length 70)
Max. Installation Height Difference m15151515303030
Heat Insulation Both liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas pipingBoth liquid and gas piping

Related Products

Premium Aesthetics
SkyAir Duct Connection Low Static Pressure - Width Compact (FDBF)
Comfortable AirflowQuiet ModeRefrigerant R32

SkyAir Duct Connection Low Static Pressure - Width Compact (FDBF)

Hidden Concealed Duct

Capacity
2 – 6 PK
Power
1.500W – 5.300W

Blends perfectly with interior design, with no visible AC unit on the wall or ceiling.

Round Flow
SkyAir Ceiling Mounted Cassette Round Flow (FCFC)
Energy Saving360° AirflowEasy Maintenance

SkyAir Ceiling Mounted Cassette Round Flow (FCFC)

Ceiling Cassette Round Flow

Energy-saving round flow ceiling Cassette AC with a cleanliness sensor and smart temperature control.

Quick Cool
SkyAir Ceiling Cassette 3x3 (FCC)
Quick Cool

SkyAir Ceiling Cassette 3x3 (FCC)

Ceiling Cassette 3x3

3x3 feet ceiling Cassette AC with fast cooling and easy maintenance.

Floor Standing
SkyAir Floor Standing (FVC)
Floor Standing

SkyAir Floor Standing (FVC)

Floor Standing

High-capacity floor standing AC unit for instant cooling in multipurpose halls and restaurants.

Need help choosing?

Find your nearest authorised dealer or calculate the capacity your room needs.